-
Contact
Sales & Customer Service
0800 612 6537 support@safelincs.co.uk Live ChatDelivery Enquiries
0800 077 6149 - Resources
Discontinued Product
This product has been discontinued.
£106.52 inc VAT
£88.77 ex VAT
Fitted with a lifetime self-charging lithium back-up battery, the Ei160eRF series of mains powered radio-interlinked alarms are ideal for use where annual battery replacement and installing interlinking cables would be unsuitable. The RadioLINK module supplied with each alarm simply plugs into the back of the unit and enables up to 12 smoke and heat alarms to wirelessly interlink within a single system. All alarms are CE marked and Kitemarked to the latest standards.
The table below shows all the units that can interlink with the EI160 Series.
Smoke and Heat Alarms - Radio
Model Number
|
Type of Unit
|
Type of Interlink
|
Ei3014 / Ei3014RF | Mains Powered Heat Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei3016 / Ei3016RF | Mains Powered Optical Smoke Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei3024 / Ei3024RF | Mains Powered Optical & Heat Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei3028 / Ei3028RF | Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei2110e / Ei2110eRF | Mains Powered Multi Sensor Smoke & Heat Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei161e / Ei161eRF | Mains Powered Ionisation Smoke Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei164e / Ei164eRF | Mains Powered Heat Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei166e / Ei166eRF | Mains Powered Optical Smoke Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei141 / Ei168RC141RC | Mains Powered Ionisation Alarm - 9V Alkaline | Hardwire or Radio Interlink |
Ei144 / Ei168RC144RC | Mains Powered Heat Alarm - 9V Alkaline | Hardwire or Radio Interlink |
Ei146 / Ei168RC146RC | Mains Powered Optical Smoke Alarm - 9V Alkaline | Hardwire or Radio Interlink |
Ei3100RF | Battery Powered Ionisation Smoke Alarm - 9V Alkaline | Radio Interlink |
Ei3103RF | Battery Powered Heat Alarm - 9V Alkaline | Radio Interlink |
Ei3105RF | Battery Powered Optical Smoke Alarm - 9V Alkaline | Radio Interlink |
Ei603RF | Battery Powered Heat Alarm - Sealed Lithium | Radio Interlink |
Ei650RF | Battery Powered Optical Smoke Alarm - Sealed Lithium | Radio Interlink |
Carbon Monoxide Alarms
Model Number
|
Type of unit
|
Type of interlink
|
Ei3018 / Ei3018RF | Mains Powered Carbon Monoxide Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei3028 / Ei3028RF | Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei262 | Mains Powered Carbon Monoxide Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei261 | Mains Powered Carbon Monoxide Alarm - Sealed Lithium | Hardwire Interlink |
Ei208WRF | Battery Powered Carbon Monoxide Detector - Sealed Lithium | Radio Iinterlink |
Ancillary Products
Model Number
|
Type of unit
|
Type of interlink
|
Ei170RF | Mains Powered Strobe and Vibration Pad for the Hearing Impaired - Sealed Lithium | Radio Interlink |
Ei407 | Battery Powered Manual Call Point - Sealed Lithium | Radio Interlink |
MCP401RC | Mains Powered Manual Call Point | Hardwire Interlink |
Ei450 | Battery Powered Fire and CO Alarm Controller - Sealed Lithium | Radio Interlink |
Ei411H | Battery Powered Locate, Silence & Test Control Switch - Sealed Lithium | Radio Interlink |
Ei410TRF | Battery Powered Test Remote - Sealed Lithium | Radio Interlink (Ei3100RF Series) |
Ei1529RC | Mains Powered Locate, Silence & Test Control Switch | Hardwire Interlink |
Ei159 | Mains Powered Smoke Alarm Locator Switch | Hardware Interlink |
Ei428 | Mains Powered 5A Relay Module | Radio Interlink |
Ei128R | Mains Powered 5A Relay Module | Hardwire Interlink |
Ei128RBU | Mains Powered 5A Relay Module with Lithium Backup Battery | Hardwire Interlink |
Y03 | Mains Powered Multi Frequency Sounder | Hardwire Interlink (via relay) |
SAB300C | Mains Powered Flashing Xenon Strobe (Clear) | Hardwire Interlink (via relay) |
SAB300R | Mains Powered Flashing Xenon Strobe (Red) | Hardwire Interlink (via relay) |
Wiring Explained
Mains powered Ei Electronics smoke and heat alarms require a 230V AC power supply and up to 12 alarms can be hardwire interlinked in one system.
To obtain a mains power supply, each alarm can be connected to the nearest lighting circuit using 2 core and earth cable with a separate, dedicated interlink cable connecting alarms where applicable. However, if possible it is recommended that any alarms connected via interlink cable are all powered from a dedicated circuit from the distribution board using 3 core and earth cable for safety during maintenance, as the interlink cable will carry power from live alarms on other power circuits. Please see the diagram below:-
Product Code |
Ei164eRF Radio-Interlinked Heat Alarm: EI164ERF |
---|---|
Brand | EI Electronics |
Back-Up Battery | Self-Charging Lifetime Lithium Battery |
Dimensions | Ei161e Ionisation Alarm: (HxDia) 54x148mm Ei166e Optical Alarm: (HxDia) 54x148mm Ei164e Heat Alarm: (HxDia) 63x148mm Ei100MRF RadioLINK Module: (HxW) 37x150mm |
Operating Temperature | 0 °C to +40 °C |
Radio-Frequency Range | Free Space: Up to 100m In Buildings: Up to 30m |
Relative Humidity | 15% to 95% |
Sound Output | 85dB |
Weight | EI164ERF: 0.543kg |
Product Datasheets |
Approved Partner
11 customers have given this product an overall rating of 4.7 out of 5
Rating: 5 / 5 Stars
Reviewed by:
Discreet and effective!
Published on: 28th October 2017
Rating: 5 / 5 Stars
Reviewed by:
Good quality, certainly for the price.
Published on: 28th October 2017
Rating: 5 / 5 Stars
Reviewed by:
Easy Set up Exceptional company to deal with
Published on: 26th June 2017
If you have any questions or would like more information about this product you can ask one of our specialists.
Live Chat Available Now