CALL OUR TEAM NOW 0800 612 6537 Lines open today 8am - 6pm

Mains Powered Heat Alarm with Self-Charging 10 Year Back-up Battery - Aico Ei164e

Discontinued Product

This product has been discontinued.

alternative product

Replacement for Ei164, Ei164RC & Ei164e Heat Alarms

  • Power: 230V mains with back-up battery
  • Back-up Battery: Self-charging lifetime battery
  • Warranty: 5 year warranty
  • Fits directly onto your current Ei164 heat alarm base
  • Fully compatible replacement for all Ei164 heat alarms
  • Ideal for kitchens, lofts, garages and workshops
  • Kitemarked to BS 5446-2: 2003

£52.31 inc VAT

£43.59 ex VAT

View Product
Product Overview

Fitted with a sealed self-charging back-up battery, the Ei164e is a 230V mains powered heat alarm that can be hard-wire interlinked with up to 12 other smoke and heat alarms within the same series. The Ei164e heat alarm is designed for use in kitchen areas (and dusty areas such as garages) and is supplied complete with Easi-fit base. Its mains powered design makes the heat alarm suitable for installations complying to BS 5839-6 Grade D1.

Please Note: these are old stock being sold on clearance with replacement dates around August 2030.

  • Power: 230V mains powered with lifetime back-up battery
  • Backup: Self-charging lithium battery
  • Warranty: 5 year warranty
  • CE marked and Kitemarked to BS 5446-2: 2003
  • Suitable for installations complying to BS 5839-6: 2019 Grade D1
  • Up to 12 units can be hard-wire interlinked within the same system
  • Heat sensor - activates at 58 °C to avoid false alarms from cooking fumes
  • Can be wirelessly interlinked using an optional RadioLINK+ module - Ei100MRF
  • Test and hush button facility
  • Memory feature - makes it easy to identify an alarm that has previously gone off
  • Suitable for kitchen areas and garages
  • Supplied with fixings; 2 x screws and 2 x rawl plugs
  • This alarm is also suitable for the updated 2022 Scottish legislation for fire alarms in homes

Interlink

The table below shows all the units that can interlink with the EI160 series.

Smoke and Heat Alarms

Model Number
Type of Unit
Type of Interlink
Ei3014 / Ei3014RF Mains Powered Heat Alarm - Sealed Lithium Hardwire Interlink
Ei3016 / Ei3016RF Mains Powered Optical Smoke Alarm - Sealed Lithium Hardwire Interlink
Ei3024 / Ei3024RF Mains Powered Optical & Heat Alarm - Sealed Lithium Hardwire Interlink
Ei3028 / Ei3028RF Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium Hardwire Interlink
Ei2110e / Ei2110eRF Mains Powered Multi Sensor Smoke & Heat Alarm - Sealed Lithium Hardwire Interlink
Ei161e / Ei161eRF Mains Powered Ionisation Smoke Alarm - Sealed Lithium Hardwire Interlink
Ei164e / Ei164eRF Mains Powered Heat Alarm - Sealed Lithium Hardwire Interlink
Ei166e / Ei166eRF Mains Powered Optical Smoke Alarm - Sealed Lithium Hardwire Interlink
Ei141 / Ei168RC141RC Mains Powered Ionisation Alarm - 9V Alkaline Hardwire Interlink
Ei144 / Ei168RC144RC Mains Powered Heat Alarm - 9V Alkaline Hardwire Interlink
Ei146 / Ei168RC146RC Mains Powered Optical Smoke Alarm - 9V Alkaline Hardwire Interlink

Carbon Monoxide Alarms

Model Number
Type of unit
Type of interlink
Ei3018 / Ei3018RF Mains Powered Carbon Monoxide Alarm - Sealed Lithium Hardwire Interlink
Ei3028 / Ei3028RF Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium Hardwire Interlink
Ei261 Mains Powered Carbon Monoxide Alarm - Sealed Lithium Hardwire Interlink

Ancillary Products

Model Number
Type of unit
Type of interlink
MCP401RC Mains Powered Manual Call Point Hardwire Interlink
Ei1529RC Mains Powered Locate, Silence & Test Control Switch Hardwire Interlink
Ei159 Mains Powered Smoke Alarm Locator Switch Hardware Interlink
Ei128R Mains Powered 5A Relay Module Hardwire Interlink
Ei128RBU Mains Powered 5A Relay Module with Lithium Backup Battery Hardwire Interlink
Y03 Mains Powered Multi Frequency Sounder Hardwire Interlink (via relay)
SAB300C Mains Powered Flashing Xenon Strobe (Clear) Hardwire Interlink (via relay)
SAB300R Mains Powered Flashing Xenon Strobe (Red) Hardwire Interlink (via relay)

Wiring Explained

Mains powered Ei Electronics smoke and heat alarms require a 230V AC power supply and up to 12 alarms can be hardwire interlinked in one system.

To obtain a mains power supply, each alarm can be connected to the nearest lighting circuit using 2 core and earth cable with a separate, dedicated interlink cable connecting all alarms. However, if possible it is recommended that the alarms are all powered from a dedicated circuit from the distribution board using 3 core and earth cable for safety during maintenance, as the interlink cable will carry power from live alarms on other power circuits. Please see the diagram below:-

Wiring Mains Powered Alarms

Technical Data
Product Code EI164E
Alternative Product Codes Ei164, Ei164e, Ei164RC, Ei164EK, Ei164RCEK
Brand EI Electronics
Back-Up Battery

Self-charging Lithium Battery

Dimensions (HxDia)

63x148mm

Operating Temperature

0°C to +40°C

Relative Humidity

15% to 95%

Sound Output

85dB

Warranty

5 Years

Weight 0.31kg
Product Datasheets

Customer Reviews

8 customers have given this product an overall rating of 4.6 out of 5

Reviews by real customers

All of our product reviews are written by real customers that have purchased this product from us and are published without modification.

Rating: 5 / 5 Stars

Reviewed by:

very easy to install

Published on: 14th August 2018

Rating: 4 / 5 Stars

Reviewed by:

Very happy with products, no problems

Published on: 29th January 2018

Rating: 5 / 5 Stars

Reviewed by:

Good quick and helpful service

Published on: 2nd December 2017

Show More

Looking for more information?

If you have any questions or would like more information about this product you can ask one of our specialists.

Live Chat Available Now
Direct Telephone 01507 464181

Settings

Colour Scheme

Light
Dark

Pricing Display

Inc VAT
Ex VAT

Cookies

By continuing to browse this site you agree to the use of cookies.