-
Contact
Sales & Customer Service
0800 612 6537 support@safelincs.co.uk Live ChatDelivery Enquiries
0800 077 6149 - Resources
Provide smoke protection for your home with the Ei140eRF mains powered 2 smoke alarms and 1 heat alarm kit. Each alarm is supplied with a Ei168RC base plate, as standard, so that they can be interlinked with no additional cables between them. Smoke alarms are ideal for bedrooms, hallways and living areas, whereas heat alarms are best suited for kitchens, garages and unoccupied loft spaces. The RF interlink can cover up to 30m indoors and is capable of linking up to 12 compatible devices, an ideal solution for properties where the mess and cost of additional cables would be unsuitable.
Please Note: These units use the radio-interlink frequency 868.499MHz. This bandwidth is restricted for safety products, therefore the chances of interference should be limited.
The table below shows all the units that can interlink with the EI140e Series.
Smoke and Heat Alarms - Radio
Model Number
|
Type of Unit
|
Type of Interlink
|
Ei3014 / Ei3014RF | Mains Powered Heat Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei3016 / Ei3016RF | Mains Powered Optical Smoke Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei3024 / Ei3024RF | Mains Powered Optical & Heat Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei3028 / Ei3028RF | Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei2110e / Ei2110eRF | Mains Powered Multi Sensor Smoke & Heat Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei161e / Ei161eRF | Mains Powered Ionisation Smoke Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei164e / Ei164eRF | Mains Powered Heat Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei166e / Ei166eRF | Mains Powered Optical Smoke Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei141 / Ei168RC141RC | Mains Powered Ionisation Alarm - 9V Alkaline | Hardwire or Radio Interlink |
Ei144 / Ei168RC144RC | Mains Powered Heat Alarm - 9V Alkaline | Hardwire or Radio Interlink |
Ei146 / Ei168RC146RC | Mains Powered Optical Smoke Alarm - 9V Alkaline | Hardwire or Radio Interlink |
Ei3100RF | Battery Powered Ionisation Smoke Alarm - 9V Alkaline | Radio Interlink |
Ei3103RF | Battery Powered Heat Alarm - 9V Alkaline | Radio Interlink |
Ei3105RF | Battery Powered Optical Smoke Alarm - 9V Alkaline | Radio Interlink |
Ei603RF | Battery Powered Heat Alarm - Sealed Lithium | Radio Interlink |
Ei650RF | Battery Powered Optical Smoke Alarm - Sealed Lithium | Radio Interlink |
Carbon Monoxide Alarms
Model Number
|
Type of unit
|
Type of interlink
|
Ei3018 / Ei3018RF | Mains Powered Carbon Monoxide Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei3028 / Ei3028RF | Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei262 | Mains Powered Carbon Monoxide Alarm - Sealed Lithium | Hardwire or Radio Interlink |
Ei261 | Mains Powered Carbon Monoxide Alarm - Sealed Lithium | Hardwire Interlink |
Ei208WRF | Battery Powered Carbon Monoxide Detector - Sealed Lithium | Radio Iinterlink |
Ancillary Products
Model Number
|
Type of unit
|
Type of interlink
|
Ei170RF | Mains Powered Strobe and Vibration Pad for the Hearing Impaired - Sealed Lithium | Radio Interlink |
Ei407 | Battery Powered Manual Call Point - Sealed Lithium | Radio Interlink |
MCP401RC | Mains Powered Manual Call Point | Hardwire Interlink |
Ei450 | Battery Powered Fire and CO Alarm Controller - Sealed Lithium | Radio Interlink |
Ei411H | Battery Powered Locate, Silence & Test Control Switch - Sealed Lithium | Radio Interlink |
Ei410TRF | Battery Powered Test Remote - Sealed Lithium | Radio Interlink (Ei3100RF Series) |
Ei1529RC | Mains Powered Locate, Silence & Test Control Switch | Hardwire Interlink |
Ei159 | Mains Powered Smoke Alarm Locator Switch | Hardware Interlink |
Ei428 | Mains Powered 5A Relay Module | Radio Interlink |
Ei128R | Mains Powered 5A Relay Module | Hardwire Interlink |
Ei128RBU | Mains Powered 5A Relay Module with Lithium Backup Battery | Hardwire Interlink |
Y03 | Mains Powered Multi Frequency Sounder | Hardwire Interlink (via relay) |
SAB300C | Mains Powered Flashing Xenon Strobe (Clear) | Hardwire Interlink (via relay) |
SAB300R | Mains Powered Flashing Xenon Strobe (Red) | Hardwire Interlink (via relay) |
Wiring Explained
Mains powered Ei Electronics smoke and heat alarms require a 230V AC power supply and up to 12 alarms can be hardwire interlinked in one system.
To obtain a mains power supply, each alarm can be connected to the nearest lighting circuit using 2 core and earth cable with a separate, dedicated interlink cable connecting alarms where applicable. However, if possible it is recommended that any alarms connected via interlink cable are all powered from a dedicated circuit from the distribution board using 3 core and earth cable for safety during maintenance, as the interlink cable will carry power from live alarms on other power circuits. Please see the diagram below:-
Product Code | EI140KIT1H2S-RF |
---|---|
Alternative Product Codes | EI144RF, EI146RF, EI168RC146RC, EI168RC144RC, EI168RC144e |
Brand | EI Electronics |
Back-Up Battery | Alarm: 9V Replaceable Alkaline (supplied) Radio Frequency Base: Rechargeable Lithium |
Dimensions (HxDia) | Smoke Alarm: 47 x 148mm Heat Alarm: 60 x 148mm |
Operating Temperature | -10°C to 40°C |
Power Consumption | 0.75 Watts |
Relative Humidity | 15% to 95% |
Sound Output | 85dB at 3 metres |
Warranty | 5-year manufacturer's warranty |
Weight | 1.42kg |
Product Datasheets |
Model | Stock | Price |
---|---|---|
Product Code: EI140KIT1H2S-RF |
Stock Level:
7 in stock Expected dispatch: Tomorrow
|
Price:
£319.97 inc VAT £266.64 ex VAT |
Approved Partner
The following delivery options are available on this product.
If you have any questions or would like more information about this product you can ask one of our specialists.
Live Chat Available Now