CALL OUR TEAM NOW 0800 612 6537 Also FREE from UK mobiles

Home Smoke and CO Alarm Starter Kit - FireAngel FAKIT2

Write a review
£142.06 inc VAT
£118.38 ex VAT
Product Overview

The FireAngel home starter kit includes three smoke alarms, one heat alarm, and two carbon monoxide alarms, all powered by sealed 10-year lithium batteries for minimal maintenance and easy DIY installation. This kit ensures robust fire detection for most homes and provides a carbon monoxide alarm to alert residents to this silent threat, often produced by malfunctioning fuel-burning appliances. The optical smoke alarms are perfect for landings, bedrooms, and living rooms, while the heat alarm is suitable for kitchens, garages, utility rooms, and unconverted loft spaces. The carbon monoxide alarms should be installed near fuel-burning appliances like gas fires, boilers, and cookers.

  • Battery: 10 year sealed lithium battery
  • Product Lifespan: 10 years
  • Warranty: 5 year warranty
  • Easy to install

FireAngel FA6620-R Optical Smoke Alarm

  • CE marked to BS EN 14604: 2005 and UKCA marked
  • Optical sensor to identify slow burning fires
  • Appropriate for installation in bedrooms, living rooms, hallways, and landings
  • Featuring a central test / hush button allowing easy weekly testing
  • The Sleep Easy™ function enables you to mute the low battery alert for up to 8 hours, ensuring an uninterrupted night's sleep

FireAngel FA6720-R Heat Alarm

  • CE marked to BS EN 14604: 2005 and UKCA marked
  • Suitable for installation in kitchens, garages, utility rooms, and unconverted loft spaces
  • Ideal for travel accommodation such as caravans and motorhomes
  • Large central test / hush button for convenient weekly testing
  • The Sleep Easy™ function function mutes the low battery chirp for up to 8 hours

FireAngel FA3820 Carbon Monoxide Detector

  • CE, UKCA and Kitemarked to BS EN 50291-1: 2018 (domestic use) and BS EN 50291-2: 2019 (camping / caravans / boats)
  • A loud 85dB audible alarm sounds when the CO level reaches 50ppm
  • The 'Pre-alarm' warning prompts ventilation of the property when low levels of CO are detected
  • Features a low volume test function
  • Silence both low battery and end of life warnings with the Sleep Easy™ function for up to 8 hours
Contents
Item
Amount
FireAngel FA6620-R Optical Smoke Alarm
3
FireAngel FA6720-R Heat Alarm
1
FireAngel FA3820 Carbon Monoxide Detector
2
Technical Data
Product Code FASTARTKIT2-HOME
Brand FireAngel
Battery Type

10 Year Sealed Lithium

Dimensions (HxDia)

Smoke Alarm: 31.5 x 118.1mm

Heat Alarm: 42 x 118mm

Dimensions (HxWxD)

Carbon Monoxide Alarm: 67 x 125 x 33mm

Operating Humidity

Smoke Alarm: Up to 90% RH (non condensing)

Heat Alarm: Up to 90% RH (non condensing)

Carbon Monoxide Alarm: 30 to 90% (non-condensing)

Operating Temperature

Smoke Alarm: +4°C to +38°C

Heat Alarm: +4°C to +38°C

Carbon Monoxide Alarm: -10 °C to +40 °C

Sensitivity

Carbon Monoxide Alarm: 50ppm (parts per million) CO gas

Sensor Type

Smoke Alarm: Optical

Heat Alarm : Thermistor Heat

Carbon Monoxide Alarm: Advanced Electrochemical

Sound Output

Smoke Alarm Full Alarm Test: 85dB at 3 metres

Smoke Alarm: Reduced Volume Test: At least 10dB below full volume

Heat Alarm Full Alarm Test: 85dB at 3 metres

Heat Alarm Reduced Volume Test: At least 10dB below full volume

Carbon Monoxide Alarm: 85dB(A) at 3 metres (minimum)

Storage Temperature

Smoke Alarm: -20°C to +60°C

Heat Alarm: -20°C to +60°C

Carbon Monoxide Alarm: -20 °C to +50 °C

Warranty

5 years

Weight 0.75kg
Product Datasheets
FAQs (11)
Q. What type of smoke alarm do I need?
A.

We recommend using an optical smoke alarm in hallways, living rooms, dining rooms and bedrooms, as they are good at detecting smouldering fires from soft furnishings and are less likely to be set off by cooking fumes from a connected kitchen.

Heat alarms are recommended for kitchens and garages as they do not sound false alarms from cooking fumes, vehicle fumes or steam.

Ionisation alarms are being phased out due to the small amount of radioactive material used in the detector chamber. Safelincs recommends optical smoke alarms where ionisation alarms were previously used.

Q. How do I test my smoke alarm and how often should I test it?
A.

We recommend testing alarms by pressing the test button built-in to the unit, as this is designed to simulate the detection of the target stimuli (usually smoke, heat, or CO) at the alarm sensor. For more detailed guidance, check the manual included with your alarm.

You should test your alarms regularly, preferably every week. Sign up to our free smoke alarm reminder service to receive regular reminders by email or text message.

Q. What is the difference between an ionisation and an optical smoke alarm?
A.

Optical smoke alarms, also known as photoelectric detectors, have a high sensitivity to large particles in the air. They are slightly quicker at detecting slow-smouldering fires that produce a lot of smoke (such as fire from soft furnishings). They are suitable for living rooms and sleeping areas and are used near kitchens as they are less prone to false alarms. 

Ionisation smoke alarms use a small amount of radioactive material in the sensor chamber to detect fires, as such they are being discontinued. Safelincs encourages customers to purchase optical smoke alarms instead.

See also heat alarms for the most suitable protection in a kitchen.

Read more about how different smoke alarms work.

Q. Where should I install my carbon monoxide alarms?
A.

CO detectors should be installed near potential sources of carbon monoxide, essentially any fuel-burning appliances such as boilers, cookers and ovens, fireplaces (both open and enclosed burners), and portable generators. As you are likely to be most affected by CO in areas of your home that you spend the most time in it is advisable to install alarms in those areas as well, such as the living room and bedrooms. It is also worth noting that while one detector is better than no detectors at all, larger homes may require several detectors to cover the property fully.

Also note that carbon monoxide has been proven to spread into neighbouring properties through open windows and, in semi-detached or terrace houses, through loft spaces. If your property has an attached garage with a connecting door through to the house, it is recommended to fit a CO alarm inside the house leading from that doorway.

Battery powered carbon monoxide alarms can typically be installed wall-mounted or left free-standing on flat, level surface.

  • Near an appliance: they should be placed within 1 to 3 metres horizontally from the appliance and between the height of the appliance to 150mm below the ceiling – i.e., not above a stove where it would be in the path of steam or fumes.
  • In living spaces: they should be positioned close to where the occupant's head is likely to be most of the time – e.g., on your bedside table.

Combined smoke & CO alarms or mains-powered CO alarms are typically installed on the ceiling and should be at least 30cm away from any wall, light fitting, or other obstruction.

Do not install CO alarms within 3 metres of doors or windows, above radiators, or immediately close to anything that gives off steam or fumes like a cooker or shower room. Similarly, it is not recommended to install detectors in dusty areas such as workshops or garages.

For more information, please check the manufacturer's instructions – you can download the PDF manual from the relevant product page on our site. You can also watch our video guide to positioning CO detectors.

Q. What are the symptoms of carbon monoxide poisoning?
A.

The symptoms of CO poisoning can range from mild flu-like symptoms such as headache, drowsiness, confusion, nausea and dizziness to more severe symptoms like breathing difficulties and irregular heartbeat. CO poisoning can ultimately lead to coma and death.

View more symptoms on our carbon monoxide information page.

Show All

Pricing & Availability

Model Stock Price
Product Code: FASTARTKIT2-HOME Stock Level:
More than 20 in stock Expected dispatch: 29th Jul
Price:

£142.06 inc VAT

£118.38 ex VAT

Delivery Options

The following delivery options are available on this product.

Standard Delivery

£3.19 inc VAT - Orders will be delivered in 2-3 working days with Evri

Next Working Day Delivery

£6.19 inc VAT - Orders will be delivered the next working day with Evri

For dispatch today order within

Excellent Warranty

This product is supplied with a 5 year manufacturers warranty as standard

Looking for more information?

If you have any questions or would like more information about this product you can ask one of our specialists.

Direct Telephone 01507 464181

Settings

Colour Scheme

Light
Dark

Pricing Display

Inc VAT
Ex VAT

Cookies

By continuing to browse this site you agree to the use of cookies.