CALL OUR TEAM NOW 0800 612 6537 Lines open today 8am - 6pm

Mains Radio-Interlinked Heat Alarm with Self-Charging 10 Year Back-up Battery - Aico Ei3014RF

Write a review
Save 8%
£107.22 inc VAT
£89.35 ex VAT
Product Overview

The Ei3014RF is a mains powered heat alarm with rechargeable lithium backup battery and is supplied with the Ei3000MRF SmartLINK module, allowing up to 12 compatible alarms to be connected wirelessly, without the need for installing interlinking cables. The Ei3000MRF also allows for hybrid interlinking, so if cabling is a preference, it means that up to 12 compatible alarms can be interlinked via a wired or wireless connection. Fitted with a high performance heat sensor, allowing the alarm to give faster responses, the SmartLINK module will soon allow for real time notifications of alarm activations to be sent directly via email or text. AudioLINK also allows you to extract real time data from the alarm directly to your smart phone.

  • 230V mains powered heat alarm
  • Fitted with a rechargeable lithium backup battery
  • Suitable for kitchen and garage installations
  • Includes the Ei3014 Heat Alarm and compatible Ei3000MRF SmartLINK Module
  • Wireless or wired interlinking with up to 12 alarms using SmartLINK
  • CE and Kitemarked to BS 5446-2: 2003
  • Suitable for installations complying to BS 5839-6: 2019 Grade D1
  • Supplied with an Easi-fit baseplate
  • High performance heat sensor for a fast response time
  • Loud 85dB warning alarm at 3m
  • Contains AudioLINK allowing users to extract real time data directly to their smart phone
  • The Ei3014 performs its own self-check every 48 seconds to check functionality
  • Memory feature - easy to identify an alarm that has previously sounded
  • Combined test and silence button
  • 5 year manufacturer's warranty
  • This alarm is also suitable for the updated 2022 Scottish legislation for fire alarms in homes

Interlink

The table below shows all the units that can interlink with the Ei3014RF.

Smoke and Heat Alarms - Radio

Model Number
Type of Unit
Type of Interlink
Ei3014 / Ei3014RF Mains Powered Heat Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei3016 / Ei3016RF Mains Powered Optical Smoke Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei3024 / Ei3024RF Mains Powered Optical & Heat Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei3028 / Ei3028RF Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei2110e / Ei2110eRF Mains Powered Multi Sensor Smoke & Heat Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei161e / Ei161eRF Mains Powered Ionisation Smoke Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei164e / Ei164eRF Mains Powered Heat Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei166e / Ei166eRF Mains Powered Optical Smoke Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei141 / Ei168RC141RC Mains Powered Ionisation Alarm - 9V Alkaline Hardwire or Radio Interlink
Ei144 / Ei168RC144RC Mains Powered Heat Alarm - 9V Alkaline Hardwire or Radio Interlink
Ei146 / Ei168RC146RC Mains Powered Optical Smoke Alarm - 9V Alkaline Hardwire or Radio Interlink
Ei3100RF Battery Powered Ionisation Smoke Alarm - 9V Alkaline Radio Interlink
Ei3103RF Battery Powered Heat Alarm - 9V Alkaline Radio Interlink
Ei3105RF Battery Powered Optical Smoke Alarm - 9V Alkaline Radio Interlink
Ei603RF Battery Powered Heat Alarm - Sealed Lithium Radio Interlink
Ei650RF Battery Powered Optical Smoke Alarm - Sealed Lithium Radio Interlink

Carbon Monoxide Alarms

Model Number
Type of unit
Type of interlink
Ei3018 / Ei3018RF Mains Powered Carbon Monoxide Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei3028 / Ei3028RF Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei262 Mains Powered Carbon Monoxide Alarm - Sealed Lithium Hardwire or Radio Interlink
Ei261 Mains Powered Carbon Monoxide Alarm - Sealed Lithium Hardwire Interlink
Ei208WRF Battery Powered Carbon Monoxide Detector - Sealed Lithium Radio Iinterlink

Ancillary Products

Model Number
Type of unit
Type of interlink
Ei170RF Mains Powered Strobe and Vibration Pad for the Hearing Impaired - Sealed Lithium Radio Interlink
Ei407 Battery Powered Manual Call Point - Sealed Lithium Radio Interlink
MCP401RC Mains Powered Manual Call Point Hardwire Interlink
Ei450 Battery Powered Fire and CO Alarm Controller - Sealed Lithium Radio Interlink
Ei411H Battery Powered Locate, Silence & Test Control Switch - Sealed Lithium Radio Interlink
Ei410TRF Battery Powered Test Remote - Sealed Lithium Radio Interlink (Ei3100RF Series)
Ei1529RC Mains Powered Locate, Silence & Test Control Switch Hardwire Interlink
Ei159 Mains Powered Smoke Alarm Locator Switch Hardware Interlink
Ei428 Mains Powered 5A Relay Module Radio Interlink
Ei128R Mains Powered 5A Relay Module Hardwire Interlink
Ei128RBU Mains Powered 5A Relay Module with Lithium Backup Battery Hardwire Interlink
Y03 Mains Powered Multi Frequency Sounder Hardwire Interlink (via relay)
SAB300C Mains Powered Flashing Xenon Strobe (Clear) Hardwire Interlink (via relay)
SAB300R Mains Powered Flashing Xenon Strobe (Red) Hardwire Interlink (via relay)

Wiring Explained

Mains powered Ei Electronics smoke and heat alarms require a 230V AC power supply and up to 12 alarms can be hardwire interlinked in one system.

To obtain a mains power supply, each alarm can be connected to the nearest lighting circuit using 2 core and earth cable with a separate, dedicated interlink cable connecting alarms where applicable. However, if possible it is recommended that any alarms connected via interlink cable are all powered from a dedicated circuit from the distribution board using 3 core and earth cable for safety during maintenance, as the interlink cable will carry power from live alarms on other power circuits. Please see the diagram below:-

Wiring Mains Powered Alarms

Technical Data
Product Code EI3014RF
Alternative Product Codes EI3014, EI3014RF, EI3000MRF
Brand EI Electronics
Back-Up Battery

10 year sealed lithium

Dimensions (HxDia)

66 x 150mm

Operating Temperature

0°C to 40°C

Relative Humidity

15% to 95% Relative Humidity

Sound Output

85dB

Weight 0.44kg
Product Datasheets
FAQs (1)
Q. What sort of smoke alarm system would I need to install for a HMO?
A.

BS 5839-6 recommends that one or two storey HMOs with an individual floor area of no more than 200sqm (not the total of both floors) should have a Grade D smoke alarm system installed. Grade D refers to mains powered smoke alarms with a back up battery power supply. The alarms can be interlinked either by wire or by radio signal and the system does not require a separate fire alarm panel. For HMOs of 3 storey or higher, a Grade A panel system would need to be installed. This can cover the whole of the building, or can be used just for the communal areas with a separate Grade D system installed for the individual dwellings. For both applications, the level of cover should be a minimum of LD3 (in all escape routes) but this may change according to the fire risk assessment.

Pricing & Availability

Model Stock Price
Product Code: EI3014RF Stock Level:
More than 20 in stock Expected dispatch: Today
Price:

£107.22 inc VAT

£89.35 ex VAT

Delivery Options

The following delivery options are available on this product.

Standard Delivery

£3.19 inc VAT - Orders will be delivered in 2-3 working days with Evri

Next Working Day Delivery

£6.19 inc VAT - Orders will be delivered the next working day with Evri

For dispatch today order within

Excellent Warranty

This product is supplied with a 5 year manufacturers warranty as standard

Looking for more information?

If you have any questions or would like more information about this product you can ask one of our specialists.

Live Chat Available Now
Direct Telephone 01507 464181

Settings

Colour Scheme

Light
Dark

Pricing Display

Inc VAT
Ex VAT

Cookies

By continuing to browse this site you agree to the use of cookies.