-
Contact
Sales & Customer Service
0800 612 6537 support@safelincs.co.uk Live ChatDelivery Enquiries
0800 077 6149 - Resources
Discontinued Product
This product has been discontinued.
The Ei3100RF is an entirely wireless, interlinking ionisation smoke alarm from the Ei3100 series. When linked in a system, if one alarm detects smoke, all alarms go off to give maximum warning time.
The table below shows all the units that can interlink with the EI3100RF.
Smoke and Heat Alarms
Model Number
|
Type of Unit
|
Type of Interlink
|
Ei3014RF | Mains Powered Heat Alarm - Sealed Lithium | Radio Interlink |
Ei3016RF | Mains Powered Optical Smoke Alarm - Sealed Lithium | Radio Interlink |
Ei3024RF | Mains Powered Optical & Heat Alarm - Sealed Lithium | Radio Interlink |
Ei3028RF | Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium | Radio Interlink |
Ei2110eRF | Mains Powered Multi Sensor Smoke & Heat Alarm - Sealed Lithium | Radio Interlink |
Ei161eRF | Mains Powered Ionisation Smoke Alarm - Sealed Lithium | Radio Interlink |
Ei164eRF | Mains Powered Heat Alarm - Sealed Lithium | Radio Interlink |
Ei166eRF | Mains Powered Optical Smoke Alarm - Sealed Lithium | Radio Interlink |
Ei168RC/141RC | Mains Powered Ionisation Alarm - 9V Alkaline | Radio Interlink |
Ei168RC/144RC | Mains Powered Heat Alarm - 9V Alkaline | Radio Interlink |
Ei168RC/146RC | Mains Powered Optical Smoke Alarm - 9V Alkaline | Radio Interlink |
Ei3100RF | Battery Powered Ionisation Smoke Alarm - 9V Alkaline | Radio Interlink |
Ei3103RF | Battery Powered Heat Alarm - 9V Alkaline | Radio Interlink |
Ei3105RF | Battery Powered Optical Smoke Alarm - 9V Alkaline | Radio Interlink |
Ei603RF | Battery Powered Heat Alarm - Sealed Lithium | Radio Interlink |
Ei650RF | Battery Powered Optical Smoke Alarm - Sealed Lithium | Radio Interlink |
Carbon Monoxide Alarms
Model Number
|
Type of unit
|
Type of interlink
|
Ei3018RF | Mains Powered Carbon Monoxide Alarm - Sealed Lithium | Radio Interlink |
Ei3028RF | Mains Powered Heat & Carbon Monoxide Alarm - Sealed Lithium | Radio Interlink |
Ei262 | Mains Powered Carbon Monoxide Alarm - Sealed Lithium | Radio Interlink |
Ei208WRF | Battery Powered Carbon Monoxide Detector - Sealed Lithium | Radio Iinterlink |
Ancillary Products
Model Number
|
Type of unit
|
Type of interlink
|
Ei170RF | Mains Powered Strobe and Vibration Pad for the Hearing Impaired - Sealed Lithium | Radio Interlink |
Ei450 | Battery Powered Fire and CO Alarm Controller - Sealed Lithium | Radio Interlink |
Ei411H | Battery Powered Locate, Silence & Test Control Switch - Sealed Lithium | Radio Interlink |
Ei407 | Battery Powered Manual Call Point - Sealed Lithium | Radio Interlink |
Ei410TRF | Battery Powered Test Remote - Sealed Lithium | Radio Interlink (Ei3100RF Series) |
Ei428 | Mains Powered 5A Relay Module | Radio Interlink |
Y03 | Mains Powered Multi Frequency Sounder | Hardwire Interlink (via relay) |
SAB300C | Mains Powered Flashing Xenon Strobe (Clear) | Hardwire Interlink (via relay) |
SAB300R | Mains Powered Flashing Xenon Strobe (Red) | Hardwire Interlink (via relay) |
Wiring Explained
Mains powered Ei Electronics smoke and heat alarms require a 230V AC power supply and up to 12 alarms can be hardwire interlinked in one system.
To obtain a mains power supply, each alarm can be connected to the nearest lighting circuit using 2 core and earth cable with a separate, dedicated interlink cable connecting alarms where applicable. However, if possible it is recommended that any alarms connected via interlink cable are all powered from a dedicated circuit from the distribution board using 3 core and earth cable for safety during maintenance, as the interlink cable will carry power from live alarms on other power circuits. Please see the diagram below:-
Product Code | EI3100RF |
---|---|
Alternative Product Codes | Ei3100, Ei3100RF |
Brand | EI Electronics |
Battery Type | 9V Alkaline |
Dimensions (HxWxD) | 140x120x45mm |
Operating Temperature | 0°C to 40°C |
Relative Humidity | 15% to 95% |
Sound Output | 85dB |
Warranty | 5 Years |
Weight | 0.19kg |
Product Datasheets |
Yes, the Ei3103 range, Ei3100RF - Ionisation Smoke Alarm Ei3105RF - Optical Smoke Alarm Ei3103RFU - Heat Alarm, interconnect with each other. If one sounds it will send a radio-signal to the other units and they will then be activated.
If one alarm was to malfunction the other units would not be affected, if it was due to alarm failure. If the fault was with the radio-interlinking signal, then all alarms that are in the chain after the faulty alarm would be affected and they would not go off.
Approved Partner
18 customers have given this product an overall rating of 4.7 out of 5
Rating: 5 / 5 Stars
Reviewed by:
Works fine, but secure syncing with other units tricky to verify. Works fine, but the yellow LED that flashes to confirm radio sync is too quick, and with 12 units connected, it's almost impossible to confirm you are secure with the other alarms - although this is just a security gizmo - all alarms will sound if in radio range of each other. Slow down the flash rate please EI, with a long pause between the count. Better still, a bi-colour LED to indicate the count start ...
Published on: 1st July 2019
Rating: 4 / 5 Stars
Reviewed by:
Good product from a trusted company I have used these smoke alarms before and only replaced them due to age.
Published on: 14th July 2018
Rating: 5 / 5 Stars
Reviewed by:
easy to install and link with the other detectors. Arrived on time, no problems with installation and link to the other detectors very well giving good early warning thoughout
Published on: 8th April 2018
If you have any questions or would like more information about this product you can ask one of our specialists.
Live Chat Available Now